Telephone:
0577-67975099
Location:Home > Product Center > Ball Valve > Q971Type a electric double clip ball valvePN16~PN64
odel pn16-pn64 electric double clip ball valve is suitable for two position cut-off and adjustment. The valve is directly connected to the actuator. The electric actuator has a built-in servo system, and there is no need to install a servo amplifier. The operation can be controlled by inputting 4-20mA signal and 220VAC power supply.
Q971Model pn16-pn64 electric double clip ball valve is suitable for two position cut-off and adjustment. The valve is directly connected to the actuator. The electric actuator has a built-in servo system, and there is no need to install a servo amplifier. The operation can be controlled by inputting 4-20mA signal and 220VAC power supply. It has the advantages of simple connection, compact structure, small size, light weight, small resistance, stable and reliable action. The actuator can be equipped with UNIC, PSQ, HQ, DHL and other electronic electric actuators or GTX, Al and other gas piston actuators according to the user's requirements.
Part name | Material Science | ||||||
---|---|---|---|---|---|---|---|
valve body | WCB | ZG1Cr18Ni9Ti | CF8 (304) |
CF3 (304L) |
ZG1Cr18Ni12Mo2Ti | CF8M(316) | CF3M (316L) |
Ball, stem | 1Cr18Ni9Ti | 0Cr19Ni9 (304) |
00Cr19Ni11 (304L) |
1Cr18Ni12Mo2Ti | 0Cr17Ni12Mo2 (316) |
00Cr17Ni12Mo2 (316L) |
|
seal ring | Polytetrafluoroethylene (PTFE), reinforced polytetrafluoroethylene (PPL), para polyphenylene flexible graphite | ||||||
Applicable media | Water, gas, steam, oil, etc | Corrosive medium such as nitric acid | Acetic acid and other corrosive media |
CHTechnical parameters of series actuators | Valve body parameters | |||
---|---|---|---|---|
Power Supply | AC200/220V,50/60Hz | Nominal diameter | DN10~150mm | |
Output torque | 50N·M~2000N·M | Nominal diameter | PN1.6 2.5 4.0 6.4 31.5MPa(customized) | |
Range of motion | 0~90° 0~360° | Leakage | Soft seal: zero leakage | |
Action time | 15 seconds / 30 seconds / 60 seconds | Executive Agency | PSQ, HQ, UNIC, 361rs can also be equipped Series of electronic electric actuators |
|
Protector | Overheating protection | Flow characteristics | Quick opening characteristic | |
ambient temperature | -30°~60° | Adjustable range | DN10-80 | DN100-150 |
250:1 | 350:1 | |||
Manual operation | Same as attached handle operation | Basic error | ±1% | |
Limit | Electrical and mechanical double limit | dead zone | ≤1% | |
Protection level | amount toIP-65 | Return difference | ≤1% | |
Position measurement | Switch or potentiometer is optional | Applicable temperature | Sealing surface | |
Drive motor | PTFE≤150℃ RTFE≤180℃ PPL≤300℃ Hard seal≤450℃ | |||
Incoming line interface | PE1/2〞Wire lock |
Test pressure | Nominal pressure(Mpa) | Pressure level(class) | JIS(Mpa) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
1.6 | 2.5 | 4.0 | 6.4 | 10.0 | 150 | 300 | 600 | 10K | 20K | |
strength test | 2.4 | 3.8 | 6.0 | 9.6 | 15.0 | 3.1 | 7.8 | 15.3 | 2.4 | 3.8 |
Sealing test | 1.8 | 2.8 | 4.4 | 7.0 | 11.0 | 2.2 | 5.6 | 11.2 | 1.5 | 2.8 |
Air tightness test | 0.5~0.7 |
1. Design and manufacture: gb12237-89, api608, API 6D, JPI 7s-48, BS5351, din3357.
2. Flange dimensions: JB / t74-90 (jb74-90), gb9112-9131, hgj44-76, sh3406, ANSI B16.5, JIS b2212-2214, NF e29-211, din2543.
3. Structural length: gb12221-89, ANSI B16.10, JIS B2002, NF e29-305, din3202.
4. Main test: JB / T 9092, API 598.
Nominal diameter DN(mm) |
Dimensions(mm) | ||||||||
---|---|---|---|---|---|---|---|---|---|
L | D | D1 | D2 | d | b | Z-Md | H | L1 | |
15 | 35 | 95 | 65 | 45 | 15 | 14 | 4-M12 | 291 | 155.2 |
20 | 38 | 105 | 75 | 55 | 19 | 14 | 4-M12 | 296 | 155.2 |
25 | 42 | 115 | 85 | 65 | 23.5 | 14 | 4-M12 | 301 | 155.2 |
32 | 50 | 135 | 100 | 78 | 30 | 16 | 4-M16 | 311 | 195 |
40 | 60 | 145 | 110 | 85 | 36 | 16 | 4-M16 | 318 | 195 |
50 | 70 | 160 | 125 | 100 | 45 | 16 | 4-M16 | 326 | 234 |
65 | 95 | 180 | 145 | 120 | 58 | 18 | 4-M16 | 336 | 234 |
80 | 118 | 195 | 160 | 135 | 67 | 20 | 8-M16 | 363 | 271 |
100 | 140 | 215 | 180 | 155 | 76 | 20 | 8-M16 | 383 | 325 |
125 | 175 | 245 | 210 | 185 | 100 | 22 | 8-M16 | 403 | 414 |
150 | 210 | 280 | 240 | 210 | 125 | 24 | 8-M16 | 418 | 420 |
1. Be careful in installation and construction, and do not hit the valve.
2. Before installation, the ball valve should be inspected to check the specification and model, and identify whether there is damage, especially for the valve stem. Turn it a few times to see if it is skewed, because Zui is prone to bump the stem during transportation. Also remove the debris in the valve.
3. When lifting the ball valve, the rope should not be tied to the hand wheel or the valve stem to avoid damage to these parts, but should be tied to the valve body.
4. The pipeline connected to the ball valve must be cleaned. Compressed air can be used to blow away iron oxide chips, mud and sand, welding slag and other impurities. These debris, not only easy to scratch the sealing surface of the ball valve, in which large particles of debris (such as welding slag), but also block the small valve, so that its failure.
5. The position of valve handle rotation should be reserved during installation. 6. The ball valve cannot be used as throttling. 7. The ball valve with transmission mechanism shall be installed vertically.
常用阀门材料允许使用压力明细介绍
常用阀门材料允许使用压力明细说明。常用阀门材质国家标准代号分类
常用阀门材质国家标准代号分类有那些,上欧为您做准确说明,请参.....What is the name.....
The name of the organization t.....Main technical r.....
The main technical requirement.....Bill of material.....
1: Screw plug: Bronze / stainl.....Set up a new ben.....
Full flow streamline design, t.....General technica.....
The adjustment of piston type .....Fast Navigation
Product Line
Recommended Products
Technical Support
Copyright:Shangou Valve Co.,Ltd Record No:; Sitemap