Telephone:
0577-67975099
Location:Home > Product Center > Ball Valve > Q671YPneumatic V-type ball valvePN16~PN25
Q671YPneumatic V-type ball valve PN16 ~ PN25 is composed of V-type valve body, pneumatic actuator and other accessories. Pneumatic V-type ball valve is a kind of advanced control valve with right angle rotation structure. V-type ball valve needs no repair for a long time and has a long service life.
Q671YPneumatic V-type ball valve PN16 ~ PN25 is composed of V-type valve body, pneumatic actuator and other accessories. Pneumatic V-type ball valve is a kind of advanced control valve with right angle rotation structure. V-type ball valve needs no repair for a long time and has a long service life. It provides you with a kind of valve with real high efficiency to control the process condition. V-type ball valve adopts double bearing structure, high mechanical stability and small starting torque, which ensures excellent sensitivity and induction speed of the valve.
Nominal pressure | Test pressure(MPa) | Applicable media | Applicable temperature | |
---|---|---|---|---|
Shell test | Sealing test | |||
1.6 | 2.4 | 1.76 | Water, oil, gas and high viscosity, containing fiber, solid particles and other media | -28℃~≤550℃ |
2.5 | 3.75 | 2.75 | ||
4.0 | 6.0 | 4.4 | ||
Application specification | Connecting flange | JB79-59 GB9113 HG20592-97 ANSI B16.5 | ||
Inspection and test | JB/T9092-99 API 598 |
Material / material code | C | P | R | |||
---|---|---|---|---|---|---|
Main parts | valve body | WCB | ZG1Cr18Ni9Ti | ZG0Cr18Ni12Mo2Ti | ||
paddles | 2Cr13 | ZG1Cr18Ni9Ti | ZG0Cr18Ni12Mo2Ti | |||
Stem | 2Cr13 | 1Cr18Ni9Ti | 0Cr18Ni12Mo2Ti | |||
seal ring | Cemented carbide | |||||
filler | Polytetrafluoroethylene, Roushi ink | |||||
Applicable conditions | Applicable media | Water, steam and oil | Nitric acid | Acetic acid | ||
Applicable temperature | -28℃~500℃ | |||||
Actuator | model | GT or AW series | ||||
Air source pressure | 0.3-0.7MPa | |||||
Executive Standards | Design and manufacture | Structural length | Flange size | Pressure temperature | Test and inspection | |
GBT/12237 | GB12221 | GB9113 | GB9131 | GB13927 |
Nominal pressure Or pressure level |
Nominal diameter(DN) | size(mm) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
(mm) | (in) | W | L | W1 | L1 | d | d1 | H1 | H | ||
PN1.6MPa | 25 | - | 50 | - | 25 | - | 64 | 38 | 57 | 200 | |
40 | - | 60 | - | 25 | - | 82 | 49 | 63 | 205 | ||
50 | - | 75 | 124 | 32 | 62 | 100 | 60 | 92 | 225 | ||
65 | - | 85 | 145 | 38 | 72.5 | 120 | 75 | 100 | 235 | ||
80 | - | 100 | 165 | 45 | 82.5 | 131 | 89 | 108 | 260 | ||
100 | - | 115 | 194 | 50 | 97 | 158 | 113 | 117 | 270 | ||
125 | - | 135 | 210 | 55 | 105 | 180 | 140 | 140 | 320 | ||
150 | - | 160 | 229 | 65 | 114.5 | 216 | 164 | 177 | 340 | ||
200 | - | 200 | 243 | 80 | 121.5 | 268 | 205 | 200 | 390 | ||
250 | - | 240 | 297 | 92 | 148.5 | 326 | 259 | 252 | 420 | ||
300 | - | - | 338 | - | 169 | - | 300 | 270 | 510 | ||
PN2.5MPa | 25 | - | 50 | - | 25 | - | 64 | 38 | 57 | 200 | |
40 | - | 60 | - | 25 | - | 82 | 49 | 63 | 205 | ||
50 | - | 75 | 124 | 32 | 62 | 100 | 60 | 92 | 225 | ||
65 | - | 85 | 145 | 38 | 72.5 | 120 | 75 | 100 | 235 | ||
80 | - | 100 | 165 | 45 | 82.5 | 131 | 89 | 108 | 260 | ||
100 | - | 115 | 194 | 50 | 97 | 158 | 113 | 117 | 270 | ||
125 | - | 135 | 210 | 55 | 105 | 180 | 140 | 140 | 320 | ||
150 | - | 160 | 229 | 65 | 114.5 | 216 | 164 | 177 | 340 | ||
200 | - | 200 | 243 | 80 | 121.5 | 268 | 205 | 200 | 390 | ||
250 | - | 240 | 297 | 92 | 148.5 | 326 | 259 | 252 | 420 | ||
300 | - | - | 338 | - | 169 | - | 300 | 270 | 510 | ||
CLASS 150 | 25 | 1 | 50 | - | 25 | - | 65 | 38 | 57 | 200 | |
40 | 1 1/2 | 60 | - | 25 | - | 84 | 49 | 63 | 205 | ||
50 | 2 | 75 | 124 | 32 | 62 | 102 | 60 | 92 | 225 | ||
65 | 2 1/2 | 85 | 145 | 38 | 72.5 | 121 | 75 | 100 | 235 | ||
80 | 3 | 100 | 165 | 45 | 82.5 | 134 | 89 | 108 | 260 | ||
100 | 4 | 115 | 194 | 50 | 97 | 172 | 113 | 117 | 270 | ||
125 | 5 | 135 | 210 | 55 | 105 | 196 | 140 | 140 | 320 | ||
150 | 6 | 160 | 229 | 65 | 114.5 | 221 | 164 | 177 | 340 | ||
200 | 8 | 200 | 243 | 80 | 121.5 | 278 | 205 | 200 | 390 | ||
250 | 10 | 240 | 297 | 92 | 148.5 | 333 | 259 | 252 | 420 | ||
300 | 12 | - | 338 | - | 169 | - | 300 | 270 | 510 |
Preparation before installation of pneumatic ball valve:
1. Ensure that the installation position of the pneumatic pipeline ball valve is in the coaxial position, and the two flanges on the pipeline shall be kept parallel to confirm that the pipeline can bear the weight of the pneumatic pipeline ball valve. If it is found that the pipeline can not bear the weight of the pneumatic pipeline ball valve, the corresponding support shall be provided for the pipeline before installation.
2. To confirm whether there are impurities and welding slag in the pipeline, the pipeline must be blown clean.
3. Check the name plate of the pneumatic pipeline ball valve, and operate the pneumatic pipeline ball valve fully open and closed for several times to confirm that the valve can work normally, and then check all details of the valve once again to ensure that the valve is intact.
4. Remove the protective covers at both ends of the valve, check whether the valve body is clean, and clean the inner cavity of the valve body. Since the sealing surface of the ball valve in the pneumatic pipeline is ball shaped, even small impurities may cause damage to the sealing surface.
Installation of pneumatic pipeline ball valve:
1. Any section of the pneumatic pipeline ball valve can be installed at the upstream end, and the handle pneumatic pipeline ball valve can be installed at any position of the pipeline. If the pneumatic pipeline ball valve with actuator (such as gearbox and electro pneumatic actuator) is equipped, it must be vertically installed, and the inlet and outlet of the valve shall be in horizontal position.
2. The sealing gasket shall be installed between the flange of the ball valve and the flange of the pipeline according to the design requirements of the pipeline.
3. The bolts on the flange shall be tightened symmetrically, successively and evenly.
4. If pneumatic and electric actuators are adopted for pneumatic pipeline ball valve, the installation of air source and power supply shall be completed according to the manual.
Inspection after installation of pneumatic pipeline ball valve:
1. After the installation, start the pneumatic pipeline ball valve to open and close several times. The action should be flexible and the force should be uniform. The pneumatic pipeline ball valve should work normally.
2. According to the design requirements of the pipeline pressure, the sealing performance of the joint surface between the pneumatic pipeline ball valve and the pipe flange is tested after pressurization.
常用阀门材料允许使用压力明细介绍
常用阀门材料允许使用压力明细说明。常用阀门材质国家标准代号分类
常用阀门材质国家标准代号分类有那些,上欧为您做准确说明,请参.....What is the name.....
The name of the organization t.....Main technical r.....
The main technical requirement.....Bill of material.....