0577-67975099

Location:Home  >  Product Center  > Butterfly Valve > D673HPneumatic quick cut off butterfly valvePN10~PN25

PRODUCTS Catalog
Butterfly Valve
CONTACT US
Telephone: 0577-67975099

D673HPneumatic quick cut off butterfly valvePN10~PN25

  • Profile:

    D673HPneumatic quick cut-off butterfly valve pn10-pn25 is widely used in food, medicine, chemical industry, petroleum, electric power, metallurgy, urban construction, light textile, papermaking and other water supply and drainage, gas pipeline as the role of regulating flow and intercepting medium.

Product overview

D673HPneumatic quick cut-off butterfly valve pn10-pn25 is widely used in food, medicine, chemical industry, petroleum, electric power, metallurgy, urban construction, light textile, papermaking and other water supply and drainage, gas pipeline as the role of regulating flow and intercepting medium. The main features of pneumatic butterfly valve are: novel and reasonable design, unique structure, light weight and quick opening and closing. Small operating torque, convenient operation, labor saving and dexterous. The valve can be installed in any position and maintained conveniently.

Connection size

D673HConnection dimension of pneumatic quick cut off butterfly valve PN10 ~ PN25(mm)

Nominal diameter Dimensions  
PN1.0 PN2.5
L1 L2 H H1 L D D1 b n-φd 1 D D1 b n-φd
250 348 159 584 595 140 375 335 16 12-18 165 375 335 24 12-18
300 348/627 176/200 635/630 645 170 440 395 16 12-22 178 440 395 24 12-22
350 378/627 176/200 660/655 645 170 490 445 16 12-22 190 490 445 24 12-22
400 432/627 206/200 750/696 745 190 540 495 16 16-22 216 540 495 24 16-22
450 524/627 228/200 805/728 745 190 595 550 16 16-22 222 595 550 24 16-22
500 524/850 228/270 850/820 745 190 645 600 20 20-22 229 645 600 26 20-22
600 524/850 228/270 905/875 970 210 755 705 20 20-26 267 755 705 26 20-26
700 648/1158 275/350 1000/1084 970 210 860 810 20 24-26 292 860 810 26 24-26
800 648/1158 275/350 1060/1084 1020 210 975 920 20 24-30 318 975 920 26 24-30
900 648/1158 275/350 1110/1084 1220 250 1075 1020 20 24-30 330 1075 1020 26 24-30
1000 715/1158 324/375 1200/1126 1220 250 1175 1120 20 28-30 410 1175 1120 26 28-30
1200 715/1158 324/375 1330/1256 1240 250 1375 1320 20 32-30 470 1375 1320 28 32-30
1400 795/1448 380/460 1540/1483 1460 300 1675 1520 20 36-30 530 1675 1520 30 36-30
1600 795/1448 380/460 1605/1540 1250 300 1790 1730 24 40-30 600 1790 1730 34 40-30
1800 1880 545 1640 1520 300 1990 1930 24 44-30 670 1990 1930 36 44-30
2000 1880 545 1740 1520 300 2190 2130 24 48-30 760 2190 2130 38 48-30

 

 

2.jpg

matters needing attention

1. Before installation, check whether the specification, pressure, temperature and corrosion resistance of butterfly valve meet the use requirements. Check whether the parts are damaged or loose.
2. The butterfly valve can be installed on the pipeline at any angle and should be closed; when welding the pipe flange, the valve sealing port should be blocked with a plate to prevent particles and sundries from damaging the sealing surface. After welding, take down the valve, clean the valve sealing surface and pipe cavity, and then install the fixed valve.
3. Please pay attention to the pressure bearing direction when the valve is closed.
4. Before installation, the sealing surface (sealing surface at both ends, sealing surface of butterfly plate and sealing surface of valve seat) shall be thoroughly cleaned to remove dust and dirt.
5. Before installation, the butterfly valve should be air tested, and the opening and closing position should be flexible, and the opening and closing position should be consistent with the position indicated by the pointer.
6. Manual operation, clockwise is off, counter clockwise is on, pointer indication is in place, it is not allowed to open and close the valve with additional force.
7. During the pressure test of the valve, it is not allowed to use single flange for installation and pressure test, but double flange installation and pressure test must be adopted. The test pressure shall comply with GB / T13927-92.
8. The bolts shall be tightened symmetrically and alternately instead of separately.
9. The limit screw has been adjusted before delivery, so it is not allowed to adjust it easily. Please refer to the manual for electric drive device.
10. When the electric butterfly valve leaves the factory, the opening and closing stroke of the control mechanism has been adjusted. In order to prevent the wrong direction when the power supply is connected, the user should first manually open it to the half open position before connecting the power for the first time, and then press the inching switch to check that the direction of the indicator wheel is consistent with the opening direction of the valve.
11. If the valve is found to be open and closed abnormally, the cause shall be found out for repair and elimination, so as to prevent the valve from being damaged due to opening and closing by means of applying force.

Related Products More