0577-67975099

Location:Home  >  Product Center  > Butterfly Valve > D943HElectric hard seal butterfly valvePN10~PN25

PRODUCTS Catalog
Butterfly Valve
CONTACT US
Telephone: 0577-67975099

D943HElectric hard seal butterfly valvePN10~PN25

  • Profile:

    D943HThe electric hard seal butterfly valve PN10 ~ PN25 is based on the introduction of foreign advanced technology. It adopts precise J-shaped elastic sealing ring and three eccentric multi-layer metal hard sealing structure. It is widely used in gold treatment, electric power, petrochemical industry, water supply and drainage, municipal construction and other industrial pipelines with medium temperature ≤ 425 ℃

Product overview

D943HThe electric hard seal butterfly valve PN10 ~ PN25 is based on the introduction of foreign advanced technology. It adopts precision J-shaped elastic sealing ring and three eccentric multi-level metal hard sealing structure. It is widely used in the industrial pipelines of gold treatment, electric power, petrochemical, water supply and drainage and municipal construction with medium temperature less than 425 ℃ for regulating flow and carrying off fluid. The valve adopts three eccentric structure. The valve seat and disc sealing surface are made of different hardness and stainless steel. It has good corrosion resistance and long service life. The valve has two-way sealing function. The product meets the national GB / T13927-92 valve pressure test standard.

Product features

1. The valve adopts three eccentric sealing structure, the valve seat and butterfly plate almost have no wear, with the sealing function of more and more tight.
2. The seal ring is made of stainless steel, which has the double advantages of metal hard seal and elastic seal. It has excellent sealing performance, corrosion resistance and long service life under low and high temperature conditions.
3. The sealing surface of disc plate is made of hardfacing cobalt base cemented carbide, which is wear resistant and has long service life
4. Large size butterfly plate adopts quilting frame structure with high strength, large flow area and small flow resistance.
5. The valve has two-way sealing function. It is not limited by the flow direction of medium or affected by the space position. It can be installed in any direction.
6. The driving device can be installed in multiple positions (90 ° or 180 ° rotation), which is convenient for users.

technical parameter

D943HMain technical parameters of electric hard seal butterfly valve PN10 ~ PN25

Nominal diameterDN(mm) 50~2000
Nominal pharmacologyPN(Mpa) 0.6 1.0 1.6 2.5
Sealing test(Mpa) 0.66 1.1 1.76 2.75
strength test(Mpa) 0.9 1.5 2.4 3.75
Applicable temperature Carbon steel: - 29 ℃~ 425 ℃, stainless steel: - 40 ℃~ 650 ℃
Applicable media Water, air, natural gas, oil and weak corrosive fluid
Leakage rate In accordance with GB / T13927-92
Driving mode Worm gear drive, electric, pneumatic and hydraulic
Parts materials
D943HMaterials of main parts and components of electric hard seal butterfly valve PN10 ~ PN25
Part name Material Science
valve body WCB、Alloy steel, stainless steel、QT450-10
Disc WCB、Alloy steel, stainless steel、QT450-10
Valve shaft 2Cr13Stainless steel, alloy steel
seal ring Stainless steel ring
filler Flexible graphite

 

Standards adopted
D943HStandard for electric hard seal butterfly valve PN10 ~ PN25
Manufacturing standards JB/T 8527-97
Flange standard GB9113-2000
Structural length standard GB12221-89
Inspection standard GB/T 13927-92
Connection size
D943HMain external connection dimensions of electric hard seal butterfly valve PN10 ~ PN25(mm)
Nominal diameter(DN) Main dimensions Flange size and bolt specification
1.0MPa 1.6MPa 2.5MPa
L H1 H D D1 n-Фd D D1 n-Фd D D1 n-Фd
50 108 530 112 165 125 4-18 165 125 4-18 165 125 4-18
65 112 530 115 185 145 4-18 185 145 4-18 185 145 8-18
80 114 565 120 200 160 4-18 200 160 8-18 200 160 8-18
100 127 600 138 220 180 8-18 220 180 8-18 235 190 8-22
125 140 640 164 250 210 8-18 250 210 8-18 270 220 8-26
150 140 705 175 285 240 8-22 285 240 8-22 300 250 8-26
200 152 775 200 340 295 8-22 340 295 12-22 360 310 12-26
250 165 945 243 395 350 12-22 405 355 12-26 425 370 12-30
300 178 1070 250 445 400 12-22 460 410 12-26 485 430 16-30
350 190 1140 280 505 460 16-22 520 470 12-26 555 490 16-33
400 216 1210 305 565 515 16-26 580 525 16-26 620 550 16-36
450 222 1335 350 615 565 20-26 640 585 16-30 670 600 20-36
500 229 1415 380 670 620 20-26 715 650 20-30 730 660 20-36
600 267 1605 445 780 725 20-30 840 770 20-33 845 770 20-39
700 292 1844 480 895 840 24-30 910 840 24-36 960 875 24-42
800 318 2040 530 1015 950 24-33 1025 950 24-39 1085 990 24-48
900 330 2255 580 1115 1050 28-33 1125 1050 28-39 1185 1090 28-48
1000 410 2380 650 1230 1160 28-36 1255 1170 28-42 1320 1210 28-56
1200 470 2640 760 1455 1380 32-39 1485 1390 32-48 1530 1420 32-56
1400 530 2886 850 1675 1590 36-42 1685 1590 36-48 1755 1640 36-62
1600 600 3156 1030 1915 1820 40-48 1930 1820 40-56 1975 1860 40-62
1800 670 3421 1230 2115 2020 44-48 2130 2020 44-56 2195 2070 44-70
2000 760 3685 1350 2325 2230 48-48 2345 2230 48-62 2425 2300 48-70
matters needing attention

1. Before installation, check whether the specification, pressure, temperature and corrosion resistance of butterfly valve meet the use requirements. Check whether the parts are damaged or loose.
2. The butterfly valve can be installed on the pipeline at any angle and should be closed; when welding the pipe flange, the valve sealing port should be blocked with a plate to prevent particles and sundries from damaging the sealing surface. After welding, take down the valve, clean the valve sealing surface and pipe cavity, and then install the fixed valve.
3. Please pay attention to the pressure bearing direction when the valve is closed.
4. Before installation, the sealing surface (sealing surface at both ends, sealing surface of butterfly plate and sealing surface of valve seat) shall be thoroughly cleaned to remove dust and dirt.
5. Before installation, the butterfly valve should be air tested, and the opening and closing position should be flexible, and the opening and closing position should be consistent with the position indicated by the pointer.
6. Manual operation, clockwise is off, counter clockwise is on, pointer indication is in place, it is not allowed to open and close the valve with additional force.
7. During the pressure test of the valve, it is not allowed to use single flange for installation and pressure test, but double flange installation and pressure test must be adopted. The test pressure shall comply with GB / T13927-92.
8. The bolts shall be tightened symmetrically and alternately instead of separately.
9. The limit screw has been adjusted before delivery, so it is not allowed to adjust it easily. If the configuration of driving device is electric or pneumatic, please refer to the manual of supporting drive device.
10. When the electric butterfly valve leaves the factory, the opening and closing stroke of the control mechanism has been adjusted. In order to prevent the wrong direction when the power supply is connected, the user should first manually open it to the half open position before connecting the power for the first time, and then press the inching switch to check that the direction of the indicator wheel is consistent with the opening direction of the valve.
11. If the valve is found to be open and closed abnormally, the cause shall be found out for repair and elimination, so as to prevent the valve from being damaged due to opening and closing by means of applying force.

Related Products More
Related Articles More
Mobile:+86-13777706603 Legal adviser: Beijing Yingke (Wenzhou) law firm Tel:0577-67975099 Address:Shangou Industrial Park, Jiaodong Road, Anfeng Industrial Zone, Yongjia Oubei, Wenzhou, Zhejiang Province

Copyright:Shangou Valve Co.,Ltd    Record No:;    Sitemap    

Friendship Links: SenAu Product website    

Telephone:
0577-67975099

Wechat service number