Telephone:
0577-67975099
Location:Home > Product Center > Butterfly Valve > D341H、D341WType a flange ventilation butterfly valvePN5~PN10
D341H、D341W The type pn5-pn10 flange ventilation butterfly valve is mainly used in the dust containing cold air or hot air gas pipeline of ventilation and environmental protection engineering in metallurgy, chemical industry, building materials, power station, glass and other industries, as a gas medium to adjust the flow or cut-off device.
D341H、D341W The type pn5-pn10 flange ventilation butterfly valve is mainly used in the dust containing cold air or hot air gas pipeline of ventilation and environmental protection engineering in metallurgy, chemical industry, building materials, power station, glass and other industries, as a gas medium to adjust the flow or cut-off device.
1. It is designed and manufactured by adopting the new structure form of welding the central line type disc plate and short structure steel plate. It has the advantages of compact structure, light weight, easy installation, small flow resistance, large flow capacity, avoiding the influence of high temperature expansion, and easy to operate;
2. There is no connecting rod, bolt, etc. inside, it works reliably and has long service life. It can be installed in multi position, not affected by the medium flow direction;
D341H、D341W Connection dimensions of PN5 ~ PN10 flange ventilation butterfly valve
Nominal diameter | Main dimensions and connection dimensions | |||||||
L | D1 | D | Z-d | H | H0 | A | B | |
50 | 108 | 110 | 140 | 4-14 | 70 | 215 | 270 | 65 |
65 | 112 | 130 | 160 | 4-14 | 80 | 235 | 270 | 65 |
80 | 124 | 150 | 190 | 4-18 | 95 | 263 | 270 | 65 |
100 | 127 | 170 | 210 | 4-18 | 105 | 283 | 270 | 65 |
125 | 140 | 200 | 240 | 8-18 | 120 | 313 | 310 | 65 |
150 | 140 | 225 | 265 | 8-18 | 132.5 | 338 | 310 | 65 |
200 | 152 | 280 | 320 | 8-18 | 160 | 493 | 365 | 90 |
250 | 165 | 335 | 375 | 12-18 | 187.5 | 550 | 365 | 90 |
300 | 178 | 395 | 440 | 12-22 | 220 | 615 | 365 | 90 |
350 | 190 | 445 | 490 | 12-22 | 245 | 678 | 365 | 90 |
400 | 216 | 495 | 540 | 16-22 | 270 | 727 | 365 | 90 |
450 | 222 | 550 | 595 | 16-22 | 297.5 | 782 | 365 | 90 |
1. Before installation, check whether the specification, pressure, temperature and corrosion resistance of butterfly valve meet the use requirements. Check whether the parts are damaged or loose.
2. The butterfly valve can be installed on the pipeline at any angle and should be closed; when welding the pipe flange, the valve sealing port should be blocked with a plate to prevent particles and sundries from damaging the sealing surface. After welding, take down the valve, clean the valve sealing surface and pipe cavity, and then install the fixed valve.
3. Please pay attention to the pressure bearing direction when the valve is closed.
4. Before installation, the sealing surface (sealing surface at both ends, sealing surface of butterfly plate and sealing surface of valve seat) shall be thoroughly cleaned to remove dust and dirt.
5. Before installation, the butterfly valve should be air tested, and the opening and closing position should be flexible, and the opening and closing position should be consistent with the position indicated by the pointer.
6. Manual operation, clockwise is off, counter clockwise is on, pointer indication is in place, it is not allowed to open and close the valve with additional force.
7. During the pressure test of the valve, it is not allowed to use single flange for installation and pressure test, but double flange installation and pressure test must be adopted. The test pressure shall comply with GB / T13927-92.
8. The bolts shall be tightened symmetrically and alternately instead of separately.
9. The limit screw has been adjusted before delivery, so it is not allowed to adjust it easily. If the configuration of driving device is electric or pneumatic, please refer to the manual of supporting drive device.
10. When the electric butterfly valve leaves the factory, the opening and closing stroke of the control mechanism has been adjusted. In order to prevent the wrong direction when the power supply is connected, the user should first manually open it to the half open position before connecting the power for the first time, and then press the inching switch to check that the direction of the indicator wheel is consistent with the opening direction of the valve.
11. If the valve is found to be open and closed abnormally, the cause shall be found out for repair and elimination, so as to prevent the valve from being damaged due to opening and closing by means of applying force.
蝶阀的产品分类介绍
蝶阀又叫翻板阀,是一种结构简单的调节阀,同时也可用于低压管道.....常用阀门材料允许使用压力明细介绍
常用阀门材料允许使用压力明细说明。常用阀门材质国家标准代号分类
常用阀门材质国家标准代号分类有那些,上欧为您做准确说明,请参.....What is the name.....
The name of the organization t.....Main technical r.....
The main technical requirement.....Bill of material.....
1: Screw plug: Bronze / stainl.....Set up a new ben.....
Full flow streamline design, t.....General technica.....
The adjustment of piston type .....Fast Navigation
Product Line
Recommended Products
Technical Support
Copyright:Shangou Valve Co.,Ltd Record No:; Sitemap
Friendship Links: SenAu Product website